1.Applicable and Description
1. Applicable Scope |
2.Type and Meaning |
HL |
R |
1000 |
- |
240 |
A |
T |
1H |
2Q |
Hongli |
Relay |
Type |
Packing Y :Individual Box Pack - : Factory Bulk Pack |
Coil voltage |
Coil Input |
Termination |
Contact Arrangment 2H:Two groups often opens
|
Contact Mode 2Q:Double1/4"QC
|
Type | HLR1000-240AT1H2Q |
Rating of current | Ie : 40A |
Rating of contacts voltage | Ue :240/277(V) |
Rating of insulation voltage | Ui : 600(V) |
Rating of coil voltage | Us: 208/240(V) |
Mechanical life | 1,000,000 times |
Electricity life | 100,000 times |
Product Explanation |
1 .The Regular Service Conditon And Installs The Condition b. Before The Use Should Inspect The Power Terminal And The Contactor
|
Conforms To National Standard And International Standard
|
1 、Conforms To UL508, IEC60947, GB14048 Standard |
2 、Approved By UL,ROHS,and ISO9001 System Certification(SGS) | |
UL Files Number: E251539 |
4.Ordering Request
In order to guarantee you use need, when you order please in detail explain:
Relay specification model, pole number, coil control voltage, fixed operating current, wiring way and packing way and so on.
If You Request As Follows: Nominal Current:40A(ACI), Working Voltage: 277V, Pole Number:One pole , Coil Control Voltage:208/240VAC, Wiring way:Double 1/4 QC. Load Current: Single-Phase Motor Controls Or linear Load, Packing: 120/Each Box (Factory Packing), Then You May Be Elect The Type :HLR1000- 240AT1H2Q |
Lifts The Samples As Follows (Contains Derivation Type From This Model)
Rating of Current |
Pole Number |
Rating of Coil Control Voltage |
Control Motor Power
|
||||
24VAC |
120VAC |
208/240VAC |
277VAC |
380/480VAC |
240VAC |
||
40A |
1P |
HLR1000- 024AT1H2Q |
HLR1000- 120AT1H2Q |
HLR1000- 240AT1H2Q |
HLR100- 277AT1H2Q |
HLR1000- 480AT1H2Q |
2.5Kw |